POS Hardware by Market: UK, Australia, Singapore and Mexico

The terminal does not change much between these four markets. The declaration does. In three of the four, the declaration is not ours to sign, and knowing which one is which saves a shipment from sitting in a bond while paperwork is redone.

Warehouse operator lifting a POS terminal out of its carton, with further terminals, power adapters and a packing list on the bench
One terminal, four destinations. The plug on the cord and the figure on the nameplate are the two parts that change between them.

What actually changes

Four markets, four sets of socket and paperwork. The hardware differences are small and the administrative ones are not, so the table below is the short version of all four country pages.

Market Plug Nominal voltage Frequency Mark or registration Receipt language Tax document
United KingdomType G, BS 1363230 V50 HzCE or UKCA, both acceptedEnglishVAT invoice
Australia and New ZealandType I, AS/NZS 3112230 V50 HzRCMEnglishTax invoice showing GST
SingaporeType G, BS 1363230 V50 HzIMDA equipment registrationEnglish, frequently with ChineseTax invoice showing GST
MexicoType B, NEMA 5-15127 V60 HzNOMSpanishCFDI

The line that decides the paperwork: who signs

Buyers ask a supplier whether it "has" the local mark. For one of these four markets the answer can be yes in the ordinary sense, and for the other three it cannot, because the mark is not issued to a factory at all. It is issued to a legal entity inside the destination country, and that entity carries the liability from then on.

Market Who may hold or sign it Can an overseas manufacturer do this What we can put in your file
United KingdomThe manufacturer can self-declare against the electrical safety and EMC regulations, so a factory can hold this oneYesThe declaration itself, plus the test file behind it
Australia and New ZealandA Responsible Supplier: an Australian entity with an ABN or a New Zealand entity with an IRD number, registered on the EESS databaseNoTest reports to the AS/NZS standards, CB certificate, certificate of conformity, label artwork
SingaporeAn ACRA-registered company holding a Telecommunication Dealer's LicenseNoTest reports and a signed supplier's declaration of conformity, which the dealer lodges
MexicoA Mexican legal entity with an RFC tax numberNoCB or IEC test report, critical components list, and a manufacturer's authorization letter naming the holder

This is the reason a sentence like "we hold RCM" or "we hold NOM" is worth one more question. What a factory holds is the test evidence and, usually, a CB certificate. What it cannot hold is an Australian Responsible Supplier registration or a Mexican NOM certificate, because both attach to a local legal entity and both lapse if that entity goes away. A supplier who says "we hold it" has either misread the scheme or is describing their importer's registration.

The useful question is not who holds the mark. It is how complete the evidence pack is when your certifier opens it, because that is the part a factory controls and the part that decides whether registration takes one week or six.

What does not change

240 V on the label, 253 V at the socket

The United Kingdom and Australia both work to a nominal 230 V with a permitted band of plus ten percent to minus six percent, which is 216.2 V to 253 V at the point of supply. New Zealand works to the same nominal value, and Western Australia still runs a 240 V standard of its own.

The adapters we publish are 110 to 250 V. That leaves 20 V of headroom above the 230 V nominal and 3 V below the top of the permitted band, which is 1.2 percent of 250 V. This is not a TillNode peculiarity: a wide-range nameplate is what the whole category uses, and the band is a supply-quality envelope rather than a voltage a terminal sits at all day. But if a site is at the top of it, put the measured voltage in the RFQ and ask for the answer in writing. Sites with rooftop solar, long rural runs and a substation next door are the ones that sit high.

Adapter input range against the permitted bands, in volts Adapter nameplate UK and AU band Mexico nominal 110 127 230 250 253
The adapter covers 110 to 250 V. The UK and Australian band runs to 253 V, so the nameplate stops 3 V below the top of it, which is 1.2 percent of 250 V.
Why we publish the gap instead of rounding it awayA specification that says 110 to 250 V and a market that permits 253 V is a 3 V question, and the only honest thing to do with a 3 V question is to name it. If your site needs written coverage to the top of the band, that belongs in the RFQ where it can be answered as a number.

The four markets

The United Kingdom is the only market here where the plug itself contains a fuse, and the fuse rating is set by the cord rather than by the terminal. It is also the market where the marking question was settled by a 2024 amendment and is still widely answered wrongly.

Australia and New Zealand share a plug and a voltage but not a regulator, and the RCM on the label belongs to a local Responsible Supplier rather than to the factory. That single fact changes what a factory is worth to an importer.

Singapore is the cheapest and fastest of the four to register and the easiest to get wrong on language, because the receipt has to print Chinese and the failure mode is a codepage rather than a font.

Mexico runs at 127 V and 60 Hz, which is close enough to the United States to be treated as the same market and far enough to matter. The hardware does not change; the nameplate does, and it has to be in Spanish.

What to send before we quote

  1. The destination country, and whether the goods are sold to a distributor or drop-shipped to end sites.
  2. Which entity will hold the local registration, and whether that entity has already been appointed.
  3. The plug type and the cord length you need, and for the United Kingdom the fuse rating you want fitted.
  4. The measured or expected supply voltage at the sites, if any of them are unusual.
  5. The receipt language and any tax wording that has to appear on the slip.

The country pages carry their own detail. The questions below apply to all four markets at once.

Frequently asked questions

Do you hold RCM, NOM, UKCA and IMDA registrations?

For the United Kingdom, yes in the ordinary sense: the manufacturer can self-declare against the electrical safety and EMC regulations, and we can supply that declaration with the test file behind it. For Australia and New Zealand, Singapore and Mexico, the registration or certificate is held by a local entity, so we supply the evidence pack and the local holder registers. We will not describe an importer registration as ours.

Can you fit the plug for my market?

We fit European, UK, Indian, US and Australian plug types. The UK and Singapore plug is Type G to BS 1363, Australia and New Zealand is Type I to AS/NZS 3112, and Mexico uses the US Type B pin pattern, so the US option covers it. Plug type is an order line, not a custom project.

Which voltage do I specify for Mexico?

127 V at 60 Hz, because that is the Mexican nominal value and it is what has to appear on the nameplate for NOM. The 110 to 250 V adapter covers it without a separate model, so nothing about the hardware changes and only the label does.

Is UKCA mandatory in the United Kingdom?

No. Since 1 October 2024 the United Kingdom recognizes CE marking indefinitely for electrical equipment and EMC, and either CE or UKCA may be used for goods placed on the market in Great Britain. Northern Ireland requires CE. Any page that still says UKCA is compulsory is describing the position before that amendment.

Can the receipt print in Spanish or Chinese?

Yes, and it is a firmware and codepage question rather than a font question. Simplified Chinese needs a GB-family codepage and traditional Chinese needs Big5, and printing one through the other produces the garbled output that gets blamed on the printer. Spanish is a single-byte codepage and is the simpler of the two.

What is the minimum order for a single-market configuration?

One unit on a standard configuration with the plug type of your choice. Logo, packaging and structural changes are OEM work with a 50-unit minimum. A single-market order is not a reason for a higher minimum.